Angsi Field/AI Insight

Good morning, User

Angsi is running 4,141 bbl/d under its optimised envelope this morning — and 3,791 bbl/d of it needs no rig. I've ranked 50 moves for you, 16 of them high priority.

Current
10,381
bbl/d
Optimised
11,682
bbl/d
Recoverable
+1,301
bbl/d · 26.3%
Without a rig
+3,791
bbl/d
Gas lift now
39.97
→ 21.01 MMscf/d
Annual value
$120.9M
$331.3k/d

Gap Decomposition

Root cause of the shortfall

26.3% below
4,141 bbl/d gap
Choke / Combined87%
+3,593 bbl/d
Well Reactivation8%
+350 bbl/d
Gas Lift Misallocation5%
+198 bbl/d

Action Priorities

Ranked by recoverable opportunity

50 to work
1
A-001-LSANDR-DP-AHIGH
+110 bbl/d

Optimise choke on A-001-LS — THP 142.1 → 172.6 psi, gas lift 0.45 → 0.21 MMscf/d

Outcome: Returns the well to its operating point on both levers. Header pressure must stay under 319 psi.

Choke Adjustment HIGH confidence
2
C-004-LSANDP-CHIGH
+110 bbl/d

Optimise choke on C-004-LS — THP 159.5 → 174 psi, gas lift 0.56 → 0.28 MMscf/d

Outcome: Returns the well to its operating point on both levers. Header pressure must stay under 319 psi.

Choke Adjustment HIGH confidence
3
A-002-SSANDR-DP-AHIGH
+109 bbl/d

Optimise choke on A-002-SS — THP 150.8 → 169.7 psi, gas lift 0.45 → 0.23 MMscf/d

Outcome: Returns the well to its operating point on both levers. Header pressure must stay under 319 psi.

Choke Adjustment HIGH confidence
4
C-005ANDP-CHIGH
+108 bbl/d

Optimise gas lift on C-005 — 0.49 → 0.23 MMscf/d

Outcome: Frees 0.26 MMscf/d of lift gas for redistribution. ML model, R² 0.93.

GL Reallocation LOW confidence
5
A-003ANDR-DP-AHIGH
+107 bbl/d

Optimise choke on A-003 — THP 237.9 → 211.8 psi, gas lift 1.22 → 0.71 MMscf/d

Outcome: Returns the well to its operating point on both levers. Header pressure must stay under 319 psi.

Choke Adjustment MEDIUM confidence
6
A-006ANDR-DP-AHIGH
+98 bbl/d

Optimise choke on A-006 — THP 118.9 → 142.1 psi, gas lift 0.55 → 0.27 MMscf/d

Outcome: Returns the well to its operating point on both levers. Header pressure must stay under 319 psi.

Choke Adjustment HIGH confidence
7
A-004-SSANDR-DP-AHIGH
+90 bbl/d

Optimise choke on A-004-SS — THP 143.6 → 162.4 psi, gas lift 0.68 → 0.32 MMscf/d

Outcome: Returns the well to its operating point on both levers. Header pressure must stay under 319 psi.

Choke Adjustment HIGH confidence
8
B-001-SSANDP-BHIGH
+350 bbl/d

Reactivate B-001-SS — 0 → 350 bbl/d at 185.7 psi THP, 0.4 MMscf/d gas lift

Outcome: Restores a shut-in producer. Requires a pressure build-up test and integrity check before bring-back.

Reactivation LOW confidence